Transducers

Flex-Core® maintains a large in-stock inventory of Current Transducers including AC, DC, RMS & Variable Frequency Current Transducers for most common applications.

Below is a list of all current transducers available through Flex-Core, however, not all models are in-stock. To check pricing and availability for a specific current transducer model, give us a call at (614) 889-6152 or use our quote request form. You can also use our live chat tool to speak directly with a sales representative.

If you have a specific application and need current transducers with a custom ratio, please contact support.

Current Transducers

AC, DIN Mount, High Accuracy, True RMS

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
MCTR0-0.1A thru 0-5A or 0-0.333V4-20mAdcLoad Trending, Motor Control, SCADA, Data Logging, Inverters, Wind TurbinesLoop Powered 15-35VdcMCTR Series Current Transducer from Flex-Core

AC, DIN Mount, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
MCT50-1A or 0-5A0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcLoad Trending, Motor Control, SCADA, Data LoggingLoop Powered 15-40Vdc, 85-135Vac, self-poweredModel# MCT5 Current Transducer from Flex-Core

AC, High Accuracy, True RMS

MODEL #PRIMARY CURRENTSECONDARY OUTPUTTYPICAL APPLICATIONTurn Ratio
4560-69.3V thru 0- 600V120VRevenue Metering, Instruments, Relays, and Controls0.58:1 - 5:1Model# 456 Potential Transformer from Flex-Core
475 0-69.3V thru 0- 600V120VRevenue Metering, Instruments, Relays, and Controls0.58:1 - 5:1Model# 475 Low Voltage Potential Transformer
4600-69.3V thru 0- 600V120VRevenue Metering, Instruments, Relays, and Controls0.58:1 - 5:1 Model #460 Potential Transformer

AC, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
3ACT 0-1A or 0-20A0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcLoad Trending, Motor Control, SCADA, Data LoggingLoop Powered 15-24Vdc, 115 or 230Vac +/-15%, self-powered Model# 3ACT_005A Current Transducer from Flex-Core
ACT0-1A or 0-20A0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcLoad Trending, Motor Control, SCADA, Data LoggingLoop Powered 15-24Vdc, 115 or 230Vac +/-15%, self-poweredModel# ACT_005A Current Transducer from Flex-Core

AC, High Accuracy, True RMS

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
3CTR 0-1A or 0-20A0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcLoad Trending, Motor Control, SCADA, Data Logging, Inverters, Wind Turbines85-265Vac/110-370VdcModel# 3CTR Current Transducer from Flex-Core
ACTR0-1A or 0-20A0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcLoad Trending, Motor Control, SCADA, Data Logging, Inverters, Wind Turbines115 or 230Vac +/-15%ACTR Series AC Current Transducers

AC, True RMS, Low Cost

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
MGT-0420-001 0-0.333V4-20mAdcLoad Trending, Motor Control, SCADA, Data Logging, Inverters, Wind TurbinesLoop Powered 8-35VdcModel# MGT Current Transducer from Flex-Core

DC, Low Cost

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
DT 0-5A thru 0-200A4-20mAdc, 0-10Vdc, 0-5Vdc or ±10Vdc (Bidirectional models only)Load Trending, Motor Control, SCADA, Data Logging, Solar+24Vac/dcModel# DT0 Current Transducer from Flex-Core

DC, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
CT7 0-0.1A thru 0-20A±1mA, ±10V, ±5V or 4-20AdcLoad Trending, Motor Control, SCADA, Data Logging, Solar85-265Vac/110-370Vdc (12V,15V, 24V, 37V,48Vdc options)Model# CT7 DC Current Transducer

AC/DC, High Accuracy, True RMS, Variable Frequency

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
CTL/CTA0-35A thru 0-40000A4-20mAdc, +/-10Vdc, +/-5Vdc, 4-12-20mALoad Trending, Motor Control, SCADA, Data Logging, Solar, VFDs, Wind Turbines115 or 230Vac +/-15% (12V, 24V, 48Vdc options)
CT8 0-0.1A thru 0-20A0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcLoad Trending, Motor Control, SCADA, Data Logging, Inverters, VFDs, Wind Turbines85-265Vac/110-370Vdc (12V,15V, 24V, 37V,48Vdc options)Model# CT8 DC Current Transducer

DC, Integral Signal Condiitoner, Low Cost

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
CT-48200-400A4-20mAdcLoad Trending, Motor Control, SCADA, Data Logging, Solar24Vdc or ac ±10%Model# CT-4820 Current Transducer from Flex-Core
CT-48120-100A thru 400A4-20mAdcLoad Trending, Motor Control, SCADA, Data Logging, Solar24Vdc or ac ±10%
CT-4809 0-400A4-20mAdcLoad Trending, Motor Control, SCADA, Data Logging, SolarLoop Powered 20-30VdcModel# CT4809 Current Transducer from Flex-Core

DC, Split-Core, Integral Signal Condiitoner

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
CTG 0-100A thru 0-5000A±10Vdc or ±5dc Load Trending, Motor Control, SCADA, Data Logging, Solar+/-15VdcModel# CTG-Split-Core DC Current Transducer

DC, Integral Signal Condiitoner, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
CTH 0-25A thru 0-1500A4-20mAdc, +/-10Vdc, +/-5Vdc, 4-12-20mALoad Trending, Motor Control, SCADA, Data Logging, Solar24Vdc or ac ± 10%Model# CTH-F-Hall Effect DC Current Transducer

AC, Watt, Watthour, Power Factor, VA, Current, Voltage, Multiple Function

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
PTB 0-150V, 0-300V, 0-600V/0-5A0-1mAdc, 4-20mAdc or 0-10VdcLoad Trending, Motor Control, SCADA, Data Logging115 or 230Vac +/-15%Model# PTB Power Transducer

Voltage Transducers

AC, DIN Mount, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
MVT 0-150V thru 0-600V0-1mAdc (5V or 10V), or 4-20mAdc, Service Monitoring, Voltage Control, SCADA, Data LoggingLoop Powered 15-40Vdc, 85-135Vac, self-poweredModel# MVT Voltage Transducer

AC, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
3AVT 0-90V thru 0-600V0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcService Monitoring, Voltage Control, SCADA, Data LoggingLoop Powered 15-24Vdc, 115 or 230Vac +/-15%, self-powered Model# 3AVT Voltage Transducer
AVT 0-90V thru 0-600V0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcService Monitoring, Voltage Control, SCADA, Data LoggingLoop Powered 15-24Vdc, 115 or 230Vac +/-15%, self-poweredModel# AVT Voltage Transducer from Flex-Core

AC, True RMS, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
3VTR 0-150V thru 0-600V0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcService Monitoring, Voltage Control, SCADA, Data Logging, Inverters, Wind Turbines85-265Vac/110-370VdcModel# 3VTR -3-in-1 RMS Voltage Transducer
AVTR 0-150V thru 0-600V0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcService Monitoring, Voltage Control, SCADA, Data Logging, Inverters, Wind Turbines115 or 230Vac +/-15%Model# AVTR Voltage Transducer from Flex-Core

AC, DIN Mount, True RMS, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
MVTR 0-150V thru 0-600V4-20mAdcService Monitoring, Voltage Control, SCADA, Data Logging, Inverters, Wind TurbinesLooped Powered 15-35VdcModel# MVTR Voltage Transducer from Flex-Core

DC, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
VT7 50mV thru 1000V+/-1mA, +/-5V, +/-10V, 4-20mAService Monitoring, Voltage Control, SCADA, Data Logging, Solar85-265Vac/110-370Vdc (12V,15V, 24V, 37V,48Vdc options)Model# VT7 Voltage Transducer from Flex-Core

AC/DC, True RMS, Variable Frequency

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
VT8 50mV thru 1000V0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcService Monitoring, Voltage Control, SCADA, Data Logging, Inverters, VFDs, Wind Turbines85-265Vac/110-370Vdc (12V,15V, 24V, 37V,48Vdc options)Model# VT8 Voltage Transducer from Flex-Core

DC, Low Cost

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
VTU 50mV thru 1000V0-1mAdc, 4-20mAdc, 0-5Vdc, 0-10VdcService Monitoring, Voltage Control, SCADA, Data Logging, Solar115 or 230Vac +/-15%Model# VTU Voltage Transducer from Flex-Core

DC, High Voltage

MODEL #INPUT RANGRANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
VTH 50mV thru 4000V0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcService Monitoring, Voltage Control, SCADA, Data Logging, Solar115VacModel# VTH Voltage Transducer from Flex-Core

AC, Watt, Watthour, Power Factor, VA, Current, Voltage, Multiple Function

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
PTB 0-150V, 0-300V, 0-600V/0-5A0-1mAdc, 4-20mAdc or 0-10VdcLoad Trending, Motor Control, SCADA, Data Logging115 or 230Vac +/-15%Model# PTB Power Transducer

Watt Transducers

DC, Watt, Hall Effect Sensor, High Current

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
PC8 0-25V thru 0-600V/0-5A ±1mAdc, ±10Vdc, ±5Vdc, 4-20mAdc or 4-12-20mAdcPower Monitoring, SCADA, Data Logging, Solar115 or 230Vac +/-15%Model# PC8 DC TO 400HZ Watt Transducer

AC, Watt, Single & Three Phase, Non Sinusoids

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
PC5 0-150V thru 0-600V/0-1A thru 0-25A±1mAdc, 4-20mAdc, 4-12-20mAdc, ±10Vdc or ±5VdcPower Monitoring, SCADA, Data Logging, Inverters, Wind TurbinesLoop Powered 15-40Vdc, 115 or 230Vac +/-10%, self-poweredModel# PC4 3-Phase AC Watt Transducer
PC4 0-150V thru 0-600V/0-1A thru 0-25A±1mAdc, 4-20mAdc, 4-12-20mAdc, ±10Vdc or ±5VdcPower Monitoring, SCADA, Data Logging, Inverters, Wind TurbinesLoop Powered 15-40Vdc, 115 or 230Vac +/-10%, self-poweredModel# PC5 Single Phase AC Watt Transducer

AC, Watts, Power Factor, Volt-Ampere, Multiple Function

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
PC20 0-150V thru 0-600V or 0-1A thru 0-20A0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcPower Monitoring, SCADA, Data Logging, Inverters, Wind Turbines115 or 230Vac +/-10%Model PC20 Phase Angle Transducers

AC, Watt, Single & Three Phase, Variable Frequency, Hall Effect Sensor

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
P 0-150V thru 0-600V/0-100A thru 0-2000A±1mAdc, ±10Vdc, ±5Vdc, 4-20mAdc ±20mAdc or 4-12-20mAdcPower Monitoring, SCADA, Data Logging, Inverters, VFDs, Wind Turbines115 or 230Vac +/-15%Model# P Variable Frequency AC Watt Transducer

AC, Watthour, Power Factor, VA, Current, Voltage, Multiple Function

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
PTB 0-150V, 0-300V, 0-600V/0-5A0-1mAdc, 4-20mAdc or 0-10VdcLoad Trending, Motor Control, SCADA, Data Logging115 or 230Vac +/-15%Model# PTB Power Transducer

AC, Single & Three Phase, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
GW50-150V thru 0-600V/0-5A±1mA, ±10V, ±5V, 4-20mA or 4-12-20mAPower Monitoring, SCADA, Data Logging115 or 230Vac +/-10%, self-poweredModel# GW5 Precision AC Watt or VAR Transducer
AGW 0-150V thru 0-600V/0-1A thru 0-20A+/-1mA, +/-10V, 4-20mAPower Monitoring, SCADA, Data Logging85-135Vac Model# AGW Precision AC Watt Transducer

AC, Watt / VAR, Single & Three Phase, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
GWV5 0-150V thru 0-600V/0-5A±1mAdc, ±10Vdc, ±5Vdc, 4-20mAdc or 4-12-20mAdcPower Monitoring, SCADA, Data Logging115 or 230Vac +/-10%, self-poweredModel# GWV5 Precision AC Watt/Var Transducer

AC, Watt / Watthour, Single & Three Phase, Multiple Function, Non Sinusoids

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
W0-150V thru 0-600V/0-1A thru 0-25A±1mAdc, 4-20mAdc, 4-12-20mAdc, ±10Vdc or ±5Vdc (kWh Pulse)Power Monitoring, SCADA, Data Logging, Inverters, Wind Turbines115 or 230Vac +/-10%, self-poweredModel# W AC Watt/Watt Hour Transducer
W4 0-150V thru 0-600V/0-1A thru 0-25A±1mAdc, 4-20mAdc, 4-12-20mAdc, ±10Vdc or ±5Vdc (kWh Pulse)Power Monitoring, SCADA, Data Logging, Inverters, Wind Turbines115 or 230Vac +/-10%, self-poweredModel# W AC Watt/Watt Hour Transducer

AC, Watt / Watthour, Single & Three Phase, Multiple Function, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
AGH0-150V thru 0-600V/0-1A thru 0-20A±1mAdc, ±10Vdc, or 4-20mAdc (kWh Pulse)Power Monitoring, SCADA, Data Logging115 or 230Vac +/-15%, self-powered Model# AGH Precision AC Watt/WattHour Transducer
GH 0-150V thru 0-600V/0-5A±1mA, ±10V, ±5V, 4-20mA or 4-12-20mA (kWh Pulse)Power Monitoring, SCADA, Data Logging90-135Vac Model# GH Watt/Watt Hour Var/VarHour Transducers

Var Transducers

AC, Watt / VAR, Single & Three Phase, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
GWV5 0-150V thru 0-600V/0-5A±1mAdc, ±10Vdc, ±5Vdc, 4-20mAdc or 4-12-20mAdcPower Monitoring, SCADA, Data Logging115 or 230Vac +/-10%, self-poweredModel# GWV5 Precision AC Watt/Var Transducer

AC, VAR/VARhour, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
VGH 0-150V thru 0-600V/0-1A thru 0-20A±1mAdc, ±10Vdc, ±5Vdc, 4-20mAdc or 4-12-20mAdc (kVARh Pulse)Reactive Power Monitoring, SCADA, Data Logging, Capacitor Banks115 or 230Vac +/-15%, self-poweredModel# VGH Watt/Watt Hour Var/VarHour Transducers

Frequency Transducers

AC, Narrow and Wide Band Frequency

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
AFT 3-575V0-1mAdc, 0-20mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcFrequency Monitoring, SCADA, Data Logging, VFDs, Wind TurbinesLoop Powered 15-24Vdc, 115 or 230Vac +/-15% Model# AFT Frequency Transducers

Phase Angle (Power Factor) Transducers

AC, Power Factor, Volt-Ampere, Multiple Function

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
PC20 0-150V thru 0-600V or 0-1A thru 0-20A0-1mAdc, 4-20mAdc, 0-10Vdc or 0-5VdcPower Monitoring, SCADA, Data Logging, Inverters, Wind Turbines115 or 230Vac +/-10%Model PC20 Phase Angle Transducers

AC, Watt, Watthour, Power Factor, VA, Current, Voltage, Multiple Function

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
PTB 0-150V, 0-300V, 0-600V/0-5A0-1mAdc, 4-20mAdc or 0-10VdcLoad Trending, Motor Control, SCADA, Data Logging115 or 230Vac +/-15%Model# PTB Power Transducer

AC, Phase Angle

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
PF5 0-95V thru 0-550V/0.02 thru 0-20A±1mAdc, ±10Vdc, 4-20mAdc or 4-12-20mAdcPower Factor Monitoring, SCADA, Data Logging, Capacitor Banks115 or 230Vac +/-10%Model# PF5 Phase Angle Transducer

Watt Hour/Var Hour Transducers

AC, Watt, Watthour, Power Factor, VA, Current, Voltage, Multiple Function

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
PTB 0-150V, 0-300V, 0-600V/0-5A0-1mAdc, 4-20mAdc or 0-10VdcLoad Trending, Motor Control, SCADA, Data Logging115 or 230Vac +/-15%Model# PTB Power Transducer

AC, Watt, Multiple Function, Non Sinusoids

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
W0-150V thru 0-600V/0-1A thru 0-25A±1mAdc, 4-20mAdc, 4-12-20mAdc, ±10Vdc or ±5Vdc (kWh Pulse)Power Monitoring, SCADA, Data Logging, Inverters, Wind Turbines115 or 230Vac +/-10%, self-poweredModel# W AC Watt/Watt Hour Transducer
W4 0-150V thru 0-600V/0-1A thru 0-25A±1mAdc, 4-20mAdc, 4-12-20mAdc, ±10Vdc or ±5Vdc (kWh Pulse)Power Monitoring, SCADA, Data Logging, Inverters, Wind Turbines115 or 230Vac +/-10%, self-poweredModel# W AC Watt/Watt Hour Transducer

AC, Watt / Watthour, Single & Three Phase, Multiple Function, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power Type
AGH0-150V thru 0-600V/0-1A thru 0-20A±1mAdc, ±10Vdc, or 4-20mAdc (kWh Pulse)Power Monitoring, SCADA, Data Logging115 or 230Vac +/-15%, self-powered Model# AGH Precision AC Watt/WattHour Transducer
GH 0-150V thru 0-600V/0-5A±1mA, ±10V, ±5V, 4-20mA or 4-12-20mA (kWh Pulse)Power Monitoring, SCADA, Data Logging90-135Vac Model# GH Watt/Watt Hour Var/VarHour Transducers

AC, VAR/VARhour, High Accuracy

MODEL #INPUT RANGEANALOG OUTPUTTYPICAL APPLICATIONInsurment Power
VGH0-1A thru 0-20A±1mAdc, ±10Vdc, ±5Vdc, 4-20mAdc or 4-12-20mAdc (kVARh Pulse)Power & Energy Monitoring, SCADA, Data Logging115 or 230Vac +/-15%, self-poweredModel# VGH Watt/Watt Hour Var/VarHour Transducers
SWH 0-115V thru 0-277V/0-100A thru 0-400AkWh PulsePower & Energy Monitoring, SCADA, Data LoggingSelf-Powered Model# SWH Watt Hour Meter with Integrated Current Transformer