FLEX-CORE® maintains a large in-stock inventory of Watt Transducers for most common applications.
Below is a list of all watt transducers including AC,DC, variable frequency current transducers available through Flex-Core, however, not all models are in-stock. To check pricing and availability for a specific watt transducer model, give us a call at (614) 889-6152 or use our quote request form. You can also use our live chat tool to speak directly with a sales representative.
If you have a specific application and need a watt transducers with a custom ratio, please contact support.
DC, Watt, Hall Effect Sensor, High Current
wdt_ID | Model # | Input Range | Analog Output | Insurment Power Type | Typical Application | Image |
---|---|---|---|---|---|---|
36 | PC8 | 0-25V thru 0-600V/0-5A | ±1mAdc, ±10Vdc, ±5Vdc, 4-20mAdc or 4-12-20mAdc | 115 or 230Vac +/-15% | Power Monitoring, SCADA, Data Logging, Solar |
AC, Watt, Single & Three Phase, Non Sinusoids
wdt_ID | Model # | Input Range | Analog Output | Insurment Power Type | Typical Application | Image |
---|---|---|---|---|---|---|
36 | PC5 | 0-150V thru 0-600V/0-1A thru 0-25A | ±1mAdc, 4-20mAdc, 4-12-20mAdc, ±10Vdc or ±5Vdc | Loop Powered 15-40Vdc, 115 or 230Vac +/-10%, self-powered |
Power Monitoring, SCADA, Data Logging, Inverters, Wind Turbines | |
37 | PC4 | 0-150V thru 0-600V/0-1A thru 0-25A | ±1mAdc, 4-20mAdc, 4-12-20mAdc, ±10Vdc or ±5Vdc | Loop Powered 15-40Vdc, 115 or 230Vac +/-10%, self-powered |
Power Monitoring, SCADA, Data Logging, Inverters, Wind Turbines |
AC, Watt, Single & Three Phase, Variable Frequency, Hall Effect Sensor
wdt_ID | Model # | Input Range | Analog Output | Insurment Power Type | Typical Application | Image |
---|---|---|---|---|---|---|
31 | P | 0-150V thru 0-600V/0-100A thru 0-2000A | ±1mAdc, ±10Vdc, ±5Vdc, 4-20mAdc ±20mAdc or 4-12-20mAdc | 115 or 230Vac +/-15% | Power Monitoring, SCADA, Data Logging, Inverters, VFDs, Wind Turbines |
AC, Watthour, Power Factor, VA, Current, Voltage, Multiple Function
wdt_ID | Model # | Input Range | Analog Output | Insurment Power Type | Typical Application | Image |
---|---|---|---|---|---|---|
32 | PTB | 0-150V, 0-300V, 0-600V/0-5A | 0-1mAdc, 4-20mAdc or 0-10Vdc | 115 or 230Vac +/-15% | Load Trending, Motor Control, SCADA, Data Logging |
AC, Single & Three Phase, High Accuracy
wdt_ID | Model # | Input Range | Analog Output | Insurment Power Type | Typical Application | Image |
---|---|---|---|---|---|---|
32 | GW5 | 0-150V thru 0-600V/0-5A | ±1mA, ±10V, ±5V, 4-20mA or 4-12-20mA | 115 or 230Vac +/-10%, self-powered | Power Monitoring, SCADA, Data Logging | |
33 | AGW | 0-150V thru 0-600V/0-1A thru 0-20A | +/-1mA, +/-10V, 4-20mA | 85-135Vac | Power Monitoring, SCADA, Data Logging |
AC, Watt / VAR, Single & Three Phase, High Accuracy
wdt_ID | Model # | Input Range | Analog Output | Insurment Power Type | Typical Application | Image |
---|---|---|---|---|---|---|
34 | GWV5 | 0-150V thru 0-600V/0-5A | ±1mAdc, ±10Vdc, ±5Vdc, 4-20mAdc or 4-12-20mAdc | 115 or 230Vac +/-10%, self-powered | Power Monitoring, SCADA, Data Logging |
AC, Watt / Watthour, Single & Three Phase, Multiple Function, Non Sinusoids
wdt_ID | Model # | Input Range | Analog Output | Insurment Power Type | Typical Application | Image |
---|---|---|---|---|---|---|
35 | W | 0-150V thru 0-600V/0-1A thru 0-25A | ±1mAdc, 4-20mAdc, 4-12-20mAdc, ±10Vdc or ±5Vdc (kWh Pulse) | 115 or 230Vac +/-10%, self-powered | Power Monitoring, SCADA, Data Logging, Inverters, Wind Turbines | |
36 | W4 | 0-150V thru 0-600V/0-1A thru 0-25A | ±1mAdc, 4-20mAdc, 4-12-20mAdc, ±10Vdc or ±5Vdc (kWh Pulse) | 115 or 230Vac +/-10%, self-powered | Power Monitoring, SCADA, Data Logging, Inverters, Wind Turbines |
AC, Watt / Watthour, Single & Three Phase, Multiple Function, High Accuracy
wdt_ID | Model # | Input Range | Analog Output | Insurment Power Type | Typical Application | Image |
---|---|---|---|---|---|---|
37 | AGH | 0-150V thru 0-600V/0-1A thru 0-20A | ±1mAdc, ±10Vdc, or 4-20mAdc (kWh Pulse) | 115 or 230Vac +/-15%, self-powered | Power Monitoring, SCADA, Data Logging | |
38 | GH | 0-150V thru 0-600V/0-5A | ±1mA, ±10V, ±5V, 4-20mA or 4-12-20mA (kWh Pulse) | 90-135Vac | Power Monitoring, SCADA, Data Logging |