Model# SG

Process Signal Conditioner

Available Downloads

Download Datasheet
Download Product Catalog
View Whitepapers & Application Notes

Need Assistance? Give us a call: 614-889-6152

SPECIFICATIONS

INPUT
Burden: (Ω)
– 1mAdc: 1K
– 5V,10V,1-5V,50mV,100mV: min. 100K
– 20mAdc: 250
– 50mAdc: 100
Overrange: 2 X rated input.
Response Time: 1 millisecond
Dielectric Test:
– Input to Output: 1000Vdc
– Input/Output to Instant Power: 1500Vdc
Instrument Power: 95-135Vac, 50-400Hz,3.5VA
– Optional 230Vac, 50-60Hz
– Optional DC Instrument Power Available. Consult factory
Termination: 14 AWG max.

OUTPUT
Accuracy:
– Set Point: ± 0.25% F.S.
– Linearity: ± 0.1% F.S.
Load on Output: (Ω)
– 1mA: 0-10K
– 5mA: 0-2.4K
– 5V,10V: >2K
– 1-5V: >2K
– 20mA: 0-600
Response Time: 10 milliseconds
Ripple: < ±0.5% F.S.
Temperature Range: -20°C to +65°C
Temperature Effect: ±0.01%/°C

APPLICATIONS

The family of SG Process Signal conditioners provide an isolated linear output signal from a standard or non-standard input process signal. Factory calibrated for various input and output signals.

FEATURES
  • Process Control
  • Signal Isolation
  • Signal Conversion