CT8 DC Current Transducer
Model# CT8

DC RMS Current Transducer

Request Quote
Detailed Model Specs
Download Datasheet
SPECIFICATIONS

INPUT
Frequency Range: dc-500Hz
Burden: VA (0.050V X F.S. Current)
Overload: 1.25 X F.S. Rating
Dielectric Test: (Input/Output/Case) 2500Vac
Instrument Power:
– 85-265Vac
– 48-420Hz
– 5VA
– 110-370Vdc
Temperature Effects: (-10° C to +60° C) + 1.0% Rdg.
Field Adjustable Cal: ± 10%

OUTPUT ACCURACY – (Includes effects of linearity and repeatability.)
– CT7 Models: ± 0.25% F.S. @ DC
– CT8 Models: ± 0.25% F.S. @ 48-420Hz
Response Time: (to 90%)
– CT7 Models: 1ms
– CT8 Models: 100 ms
Ripple: <1.0% F.S.
Output Loading (Ω)
– 0-1mA = 0-10K
– 5V & 10V = >2K
– 20mA = 0-500
Weight: 1.5Lbs.

APPLICATIONS
  • Accurate measurement of current waveforms containing DC and non-sinusoidal AC components.
  • Low current measurement.
FEATURES
  • Input/output isolation of 2500V.
  • The CT8 provides an output which is directly proportional to the RMS value of AC and/or DC input signal.